Aim

Operate the counters 7490, 7493.

Apparatus Required:

Logic trainer kit, Counter ICs- 7490, IC - 7493 wires.

Theory

Asynchronous 74LS90 Decade Counter Digital counters count upwards from zero to some pre-determined count value on the application of a clock signal. Once the count value is reached, resetting them returns the counter back to zero to start again. A decade counter counts in a sequence of ten and then returns back to zero after the count of nine. Obviously to count up to a binary value of nine, the counter must have at least four flip-flops within its chain to represent each decimal digit as shown.

BCD Counter StateDiagram

The 74LS90 BCD Counter The 74LS90 integrated circuit is basically a MOD-10 decade counter that produces a BCD output code. The 74LS90 consists of four master-slave JK flip-flops internally connected to provide a MOD-2 (count-to-2) counter and a MOD-5 (count-to-5) counter. The 74LS90 has one independent toggle JK flip-flop driven by the CLK A input and three toggle JK flip-flops that form an asynchronous counter driven by the CLK B input as shown.

74LS90 BCD Counter

The counters four outputs are designated by the letter symbol Q with a numeric subscript equal to the binary weight of the corresponding bit in the BCD counter circuits code. So for example, QA, QB, QC and QD. The 74LS90 counting sequence is triggered on the negative going edge of the clock signal, that is when the clock signal CLK goes from logic 1 (HIGH) to logic 0 (LOW). The additional input pins R1 and R2 are counter “reset” pins while inputs S1 and S2 are “set” pins. When connected to logic 1, the Reset inputs R1 and R2 reset the counter back to zero, 0 (0000), and when the Set inputs S1 and S2 are connected to logic 1, they Set the counter to maximum, or 9 (1001) regardless of the actual count number or position.

Procedure:

  1. Connections are given as per circuit diagram.
  2. Logical inputs are given as per circuit diagram.
  3. Observe the output and verify the truth table.
  4. Result:

    Thus the Counters were designed and their truth table is verified.

    Precautions

  5. All connections should be made neat and tight.
  6. Digital lab kits and ICs should be handled with utmost care.
  7. While making connections main voltage should be kept switched off.
  8. Never touch live and naked wires.